+61 (0)2 4903 8900
Quick Quote/ Contact Us

If you would like to discuss a project or receive a quote for any of our industry leading products and services please fill in the form below.

MagnaDrive Coupling Vibration Success

Nothwestern U.S. Forest Products Company uses MagnaDrive MagnaGuard Econimizer to eliminate vibration.

1.0 Problem

A Forest Products Company located in the Pacific Northwest was experiencing repeated failures in their Clean Condensate Pumps due to extremely high levels of vibration in the system that were the result of thermal expansion in the system piping and the pump shaft. Vibration amplitude levels of over 0.4 in/sec (RMS velocity) were literally shaking the pump apart. According to the Maintenance Crew, the condensate pump was being replaced between 3 and 4 times every year as a result of the vibration.

2.0 Solution

MagnaDrive Corporation proposed the installation of a MagnaGuard Economizer (MGE) as a replacement for the existing rigid coupling. Because this was a 100 Hp motor running at 3600 rpm, an MGE- 11 coupling was selected. Removal of the original coupling and installation of the MGE-11 was done without moving either the pump or the motor and only took about an hour to complete.

3.0 Result

After successful installation of the MGE-11 Coupling the customer reports the following results:

    • Vibration levels dropped from 0.431 in/sec to 0.116 in/sec RMS velocity on the inboard side of the pump and from 0.286 in/sec to 0.087 in/sec RMS velocity on the outboard side.

vibration success2 vibration success3

vibration success4 vibration success5

  • No maintenance has been required after installation.
  • The pump is lasting longer. Instead of replacing the pump 3–4 times each year at a cost of $5,000, the plant expects to not have to replace the pump ever!

4 outages X 2 man-days/outage X $600/man-day = $4,800 annual labor savings.

4 replacements X $5,000/pump = $20,000 annual equipment savings.

Total Annual Savings = $24,800.

vibration success2When asked to summarize their experience with MagnaDrive, the customer expressed complete satisfaction with both the MGE Coupling and with the service they received from the MagnaDrive Applications and Sales personnel.

   All Case Studies

Case Studies

10,000 kg Grease Tank Solution Learn More 10,000 kg Grease Tank Solution

In early 2022 IRS was commissioned by a client to design and build a custom 10,000kg Grease Tank Solution. Features included: Overfill protection, Heater - Thermostat controlled, Sim Card for data transfer, Internal pressure relief and much more.

Underground 30,000 Litre Fuel Tank Module Learn More Underground 30,000 Litre Fuel Tank Module

Integrated Reliability Solutions was commissioned to design and build a 30,000 litre underground refuelling solution for a client in May 2022. 

Water Cannon Repair Learn More Water Cannon Repair

Integrated Reliability Solutions were approached by one of the Hunter Valley coal mines to inspect and come up with a suitable repair for the leaking water cannons. On inspection of the water cannon, it was noted that a number of components had worn due to lack of lubrication which allowed the water to leak when not in use.

Breather and Sampling Point Audit - Nth Queensland Learn More Breather and Sampling Point Audit - Nth Queensland

Glencore site Collinsville CHPP had requested that we undertake an audit on their current Breather and Sampling Points, to identify opportunities to improve the cleanliness of the air entering the compartments, oil and the accuracy and process of taking oil samples. 

MagnaDrive saves Plant Feed Conveyor Learn More MagnaDrive saves Plant Feed Conveyor

On the 4th of November 2007, the plant feed conveyor failed to start after the operator attempted to restart operations following a plant stoppage.

MagnaDrive Coupling Vibration Success Learn More MagnaDrive Coupling Vibration Success

Nothwestern U.S. Forest Products Company uses MagnaDrive MagnaGuard Econimizer to eliminate vibration.

MagnaDrive Coupling Screw Pump Learn More MagnaDrive Coupling Screw Pump

City of Eugene, Oregon – Wastewater Division – MagnaDrive Magnetic Coupling on Archimedean Screw Pump

MagnaDrive Coupling Chilled Water Pump Learn More MagnaDrive Coupling Chilled Water Pump

Washington Mutual Tower in Seattle, Washington Replaces Flexible Coupling with MagnaDrive ASD

MagnaDrive Coupling Air Preheater Learn More MagnaDrive Coupling Air Preheater

Minnesota Power was experiencing vibration problems on their Air Pre-Heaters. In an effort to correct this problem, Minnesota Power implemented a preventative maintenance procedure that required all couplings to be re-greased during every outage.

Hose Down Pump Learn More Hose Down Pump

The Magnadrive Adjustable Speed Drive Coupling (ASD) was installed on the Hose Down Pump at South Walker Creek CHPP on the 4th October 2007.

Bearing Skidding Learn More Bearing Skidding

Over the last three years IRS has been monitoring motor bearings displaying various stages of fatigue.

Electric Motor Bearing Defects Learn More Electric Motor Bearing Defects

The site was experiencing a high frequency of electric motor bearing faults. Condition monitoring reports had identified specific motors as manifesting bearing defects and had suggested that a “lack of lubricant” was a significant factor contributing to the defects.

Grease Contamination Learn More Grease Contamination

Over the course of several months, site maintenance personnel observed that lubrication system components were failing at a rate higher then what would normally be expected.